OmniX™ — Integrated Patient Monitoring System

Real-time fall detection, room-level location telemetry, humidity-based diaper wetness sensing, and cloud analytics — purpose-built for assisted living and long-term care facilities.

Alert latency
<500 ms
Beacon battery
6–12 months (CR2450)
Designed for
Assisted living & nursing homes

This page summarizes the OmniX product disclosure document. For the full regulatory disclosure see the product PDF.

Core Capabilities

  • Fall Detection — multi-phase algorithm (free-fall → impact → orientation) with <500ms alert latency.
  • Wet Diaper Sensing — continuous humidity monitoring with configurable thresholds for proactive alerts.
  • Diaper Change Acknowledgement — long-press button (≥5s) logging and audit trail.
  • Real-time Dashboard & APIs — MQTT/TLS to AWS IoT, REST + WebSocket for integrations and analytics.
  • Offline Resilience — event buffering and automatic sync when connectivity resumes.

Controller CPU: ESP32-S3 Dual Core @240MHz
Display: 3.5" TFT (OmniX-S)
BLE: BLE 5.0 (advertising + data)
Beacon Sensors: 3-axis accel, humidity, temperature, button
Battery: CR2450 (6–12 months)
Cloud: AWS; MQTT/TLS; OAuth2 APIs

Performance numbers are from lab validation and product disclosure.


Use cases

Designed for assisted living, memory care, nursing homes and homecare deployments — to reduce routine checks and provide event-driven caregiver alerts.

Technical Highlights
Fall detection

Validated sensitivity ≥94% in controlled studies; multi-stage algorithm reduces false positives.

Location & Coverage

Room-level accuracy via RSSI + multi-controller triangulation. Typical ranges: OmniX-S ~4m, OmniX-D up to ~15m (environment dependent).

Humidity Detection

Humidity sensors ±3% RH; configurable thresholds (typical 60–80% RH); temperature spike used as complementary indicator.

Standards & Security

EMC / FCC / IEC test reports, TLS 1.2/1.3 encryption, GDPR/HIPAA design considerations, SBOM & vulnerability policy.

Downloadable resources
  • Full Product Disclosure (PDF)
  • IFU / Quick Start Guides
  • Clinical Validation & Test Reports
Deployment sizes
Small
Up to 10 rooms — OmniX-S with cloud
Medium / Large
Floor / campus deployments — mix OmniX-D and OmniX-S

Safety, Warnings & Limitations

Safety and regulatory details are summarized from the OmniX Product Disclosure.

Contact / Request Demo

Provide facility name, contact details, and deployment size for the fastest response.

GAVIX Corporation
Email: info@gavixtech.com • Support: support@gavixtech.com
Product page: www.gavixtech.com/omnix